最近有两台V240的机器硬盘出现报错,A机是c1t2d0经常报,B机是四块硬盘都会报,相对来说不那么频繁。
最后采取的方案是,更换A机的c1t2d0,更换B机的两块硬盘背板。
硬件都是昨晚更换的,B机到现在为止都比较正常,没有再出现报错。
A机新硬盘插上之后,只要有IO就一直在报和之前相同的硬件错误。
难道也要换背板了吗?好像V240的这个问题还比较普遍,讨论一下。
================================================
Jun 4 09:34:06 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:06 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:34:09 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] ASC: 0x29 (bus device reset message occurred), ASCQ: 0x3, FRU: 0x4
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:34:10 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:34:11 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:34:12 Deme Error for Command: read(10) Error Level: Fatal
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:34:12 Deme Error for Command: write(10) Error Level: Informational
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Requested Block: 6260192 Error Block: 6260192
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Sense Key: Soft Error
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] ASC: 0x5d (drive operation marginal, service immediately (failure prediction threshold exceeded)), ASCQ: 0x0, FRU: 0x10
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:40:31 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:40:31 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:40:32 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1
:
Jun 4 09:40:32 Deme Error for Command: read(10) Error Level: Retryable
===================================================
最后采取的方案是,更换A机的c1t2d0,更换B机的两块硬盘背板。
硬件都是昨晚更换的,B机到现在为止都比较正常,没有再出现报错。
A机新硬盘插上之后,只要有IO就一直在报和之前相同的硬件错误。
难道也要换背板了吗?好像V240的这个问题还比较普遍,讨论一下。
================================================
Jun 4 09:34:06 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:06 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:34:09 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] Sense Key: Unit Attention
Jun 4 09:34:09 Deme scsi: [ID 107833 kern.notice] ASC: 0x29 (bus device reset message occurred), ASCQ: 0x3, FRU: 0x4
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:34:10 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:10 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:34:11 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:11 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:34:12 Deme Error for Command: read(10) Error Level: Fatal
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:34:12 Deme Error for Command: write(10) Error Level: Informational
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Requested Block: 6260192 Error Block: 6260192
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] Sense Key: Soft Error
Jun 4 09:34:12 Deme scsi: [ID 107833 kern.notice] ASC: 0x5d (drive operation marginal, service immediately (failure prediction threshold exceeded)), ASCQ: 0x0, FRU: 0x10
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:40:31 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:40:31 Deme Error for Command: read(10) Error Level: Retryable
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Requested Block: 6102832 Error Block: 6102832
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Vendor: SEAGATE Serial Number: 073746YH0A
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] Sense Key: Media Error
Jun 4 09:40:31 Deme scsi: [ID 107833 kern.notice] ASC: 0x11 (unrecovered read error), ASCQ: 0x0, FRU: 0xf
Jun 4 09:40:32 Deme scsi: [ID 107833 kern.warning] WARNING: /pci@1c,600000/scsi@2/sd@2,0 (sd1

Jun 4 09:40:32 Deme Error for Command: read(10) Error Level: Retryable
===================================================
作者: sunshiene 发布时间: 2010-06-04
240一个机器有两个硬盘背板啊?
作者: Tdog 发布时间: 2010-06-04
回复 Tdog
是啊,4块盘,上下两个背板。
A机那块盘现在只要有写数据,其他窗口的访问就会特别慢。硬盘应该没这么脆弱啊,nnd背板!
是啊,4块盘,上下两个背板。
A机那块盘现在只要有写数据,其他窗口的访问就会特别慢。硬盘应该没这么脆弱啊,nnd背板!
作者: sunshiene 发布时间: 2010-06-04
相关阅读 更多
热门阅读
-
office 2019专业增强版最新2021版激活秘钥/序列号/激活码推荐 附激活工具
阅读:74
-
如何安装mysql8.0
阅读:31
-
Word快速设置标题样式步骤详解
阅读:28
-
20+道必知必会的Vue面试题(附答案解析)
阅读:37
-
HTML如何制作表单
阅读:22
-
百词斩可以改天数吗?当然可以,4个步骤轻松修改天数!
阅读:31
-
ET文件格式和XLS格式文件之间如何转化?
阅读:24
-
react和vue的区别及优缺点是什么
阅读:121
-
支付宝人脸识别如何关闭?
阅读:21
-
腾讯微云怎么修改照片或视频备份路径?
阅读:28