还是3310更换控制器问题
时间:2010-09-10
来源:互联网
新上的控制器 4.13B
插上后分别用 sccli>show red
分别显示: scanning , detected , enabled
可是过了几分钟就 变成 failed
是什么原因啊?
作者: rmb 发布时间: 2010-09-10
作者: rmb 发布时间: 2010-09-10
作者: rmb 发布时间: 2010-09-10
Vendor: SUN
Product: StorEdge 3310
Revision: 413B
NVRAM Defaults: 413B 3310 S440S
Bootrecord Version: 1.31G
Serial Number: 0942A9
IP Address: 192.168.1.100
Ethernet Address: 00:C0:FF:89:42:A9
sccli> show saf-te
Ch Id Chassis Vendor Product ID Rev Package
---------------------------------------------------------
0 14 0942A9 SUN StorEdge 3310 A 1170 1170
sccli> show red
Primary controller serial number: 90723
Primary controller location: N/A
Redundancy mode: Active-Active
Redundancy status: Failed
Secondary controller serial number: 89749
作者: rmb 发布时间: 2010-09-10
作者: twinklezcf 发布时间: 2010-09-10
作者: rmb 发布时间: 2010-09-10
作者: rmb 发布时间: 2010-09-10
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 4045104 (311)
Thu Sep 09 06:30:15 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:25:33 2010
[Primary] Warning
CHL:0 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:25:33 2010
[Primary] Warning
CHL:2 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:25:33 2010
[Primary] Alert
Controller ALERT: Redundant Controller Failure Detected
Fri Sep 10 00:25:34 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:50:09 2010
[Primary] Notification
Controller Initialization Completed
Fri Sep 10 00:50:09 2010
[Primary] Alert
Peripheral Device ALERT: Board1 Cold Temperature Detected(52.5(C) )
Fri Sep 10 00:50:09 2010
[Primary] Alert
Peripheral Device ALERT: Board2 Cold Temperature Detected(41.0(C) )
Fri Sep 10 00:50:10 2010
[Primary] Notification
Controller Default Write Policy Restore
Fri Sep 10 00:50:10 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:50:18 2010
[Primary] Notification
Controller BBU is Charging !
Fri Sep 10 00:50:20 2010
[Primary] Alert
Force Controller Write-Through on Trigger Cause
Fri Sep 10 00:50:20 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:52:24 2010
[Primary] Warning
CHL:0 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:52:24 2010
[Primary] Warning
CHL:2 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:52:24 2010
[Primary] Alert
Controller ALERT: Redundant Controller Failure Detected
Fri Sep 10 00:52:26 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
sccli> show event
Fri Aug 13 00:21:11 2010
[Primary] Notification
Controller Initialization Completed
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:0 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:1 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:2 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:3 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:4 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:5 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:8 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:9 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:10 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:11 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
LG:0 NOTICE: CHL:0 ID:12 Starting Media Scan
Fri Aug 13 00:21:11 2010
[Primary] Notification
Controller BBU is Charging !
Fri Aug 13 00:21:12 2010
[Primary] Alert
Force Controller Write-Through on Trigger Cause
Fri Aug 13 01:34:53 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 301CFA (311)
Fri Aug 13 01:34:56 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 301D02 (311)
Fri Aug 13 01:34:58 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Aug 13 02:24:32 2010
[Primary] Notification
NOTICE: Controller BBU Fully Charged !
Fri Aug 13 02:24:32 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Mon Aug 16 05:27:23 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 3360990 (311)
Mon Aug 16 05:27:23 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Tue Aug 24 06:19:21 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 2BC6660 (311)
Tue Aug 24 06:19:21 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Aug 27 14:34:29 2010
[Primary] Notification
Controller BBU is Charging !
Fri Aug 27 14:34:30 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Aug 27 17:15:06 2010
[Primary] Notification
NOTICE: Controller BBU Fully Charged !
Fri Aug 27 17:15:07 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Sat Aug 28 03:19:00 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 3725D00 (311)
Sat Aug 28 03:19:00 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Mon Aug 30 03:43:59 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 248FF90 (311)
Mon Aug 30 03:43:59 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Thu Sep 02 19:54:37 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 6F86C00 (311)
Thu Sep 02 19:54:37 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Tue Sep 07 18:11:14 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 2CC8850 (311)
Tue Sep 07 18:11:15 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Wed Sep 08 13:35:41 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 187DA00 (311)
Wed Sep 08 13:35:42 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Wed Sep 08 20:34:35 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 2751FA0 (311)
Wed Sep 08 20:34:36 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Thu Sep 09 06:30:15 2010
[Primary] Warning
CHL:0 ID:10 Drive NOTIFY: Media Error Encountered - 4045104 (311)
Thu Sep 09 06:30:15 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:25:33 2010
[Primary] Warning
CHL:0 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:25:33 2010
[Primary] Warning
CHL:2 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:25:33 2010
[Primary] Alert
Controller ALERT: Redundant Controller Failure Detected
Fri Sep 10 00:25:34 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:50:09 2010
[Primary] Notification
Controller Initialization Completed
Fri Sep 10 00:50:09 2010
[Primary] Alert
Peripheral Device ALERT: Board1 Cold Temperature Detected(52.5(C) )
Fri Sep 10 00:50:09 2010
[Primary] Alert
Peripheral Device ALERT: Board2 Cold Temperature Detected(41.0(C) )
Fri Sep 10 00:50:10 2010
[Primary] Notification
Controller Default Write Policy Restore
Fri Sep 10 00:50:10 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:50:18 2010
[Primary] Notification
Controller BBU is Charging !
Fri Sep 10 00:50:20 2010
[Primary] Alert
Force Controller Write-Through on Trigger Cause
Fri Sep 10 00:50:20 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
Fri Sep 10 00:52:24 2010
[Primary] Warning
CHL:0 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:52:24 2010
[Primary] Warning
CHL:2 Drive Channel Notification: SCSI Bus Reset Issued
Fri Sep 10 00:52:24 2010
[Primary] Alert
Controller ALERT: Redundant Controller Failure Detected
Fri Sep 10 00:52:26 2010
[Primary] Warning
CHL:0 ID:11 Drive NOTIFY: Media Error Encountered - 302113 (311)
作者: rmb 发布时间: 2010-09-10

作者: dotallstar 发布时间: 2010-09-10
热门阅读
-
office 2019专业增强版最新2021版激活秘钥/序列号/激活码推荐 附激活工具
阅读:74
-
如何安装mysql8.0
阅读:31
-
Word快速设置标题样式步骤详解
阅读:28
-
20+道必知必会的Vue面试题(附答案解析)
阅读:37
-
HTML如何制作表单
阅读:22
-
百词斩可以改天数吗?当然可以,4个步骤轻松修改天数!
阅读:31
-
ET文件格式和XLS格式文件之间如何转化?
阅读:24
-
react和vue的区别及优缺点是什么
阅读:121
-
支付宝人脸识别如何关闭?
阅读:21
-
腾讯微云怎么修改照片或视频备份路径?
阅读:28