当前位置:首页 → 问答吧 → 急救:Netra t1405

急救:Netra t1405

时间:2010-09-09

来源:互联网

硬件:Netra t1405  系统大概是:SUNOS 5.6

前面板FAULT黄色灯在闪,POWER灯绿色长亮,SYSTEM灯不亮,打开前面板右上角盖,看风扇不转,经过排除发现断开PSU3后风扇开始转了,

用25针串口线连接serial ports A没有输出,远程telnet无法连接,只好连接lom口,输出如下:
lom>environment
Fault  3Hz
Alarm1 OFF
Alarm2 OFF
Alarm3 OFF

Fans:
1 OK standby
2 OK standby
3 OK standby
4 OK standby

PSUs:
1 Output failed standby
2 Output failed standby
3 Output failed standby
lom>show
model Netra t140x
hostname prestat-serv
eventlog
  PSU 2 Output failed
  PSU 2 OK
  PSU 2 Output failed
  PSU 2 OK
  PSU 2 Output failed
  PSU 2 OK
  PSU 2 Output failed
  power off
  PSU 1 Output failed
  PSU 3 Output failed
first fatal error
  Fan 2 failed

断开PSU3后:
lom>show
model Netra t140x
hostname prestat-serv
eventlog
  PSU 3 Input failed
  PSU 2 OK
  PSU 1 Output failed
  PSU 2 Output failed
  PSU 3 OK
  Fault LED 3Hz
  PSU 3 Output failed
  PSU 3 Input failed
  PSU 1 OK
  PSU 2 OK
first fatal error
  Fan 2 failed
lom>environment
Fault  3Hz
Alarm1 OFF
Alarm2 OFF
Alarm3 ON

Fans:
1 OK standby
2 OK standby
3 OK standby
4 OK standby

PSUs:
1 OK standby
2 OK standby
3 Input failed standby

大虾帮忙解读一下该怎么处理

作者: dd890523   发布时间: 2010-09-09

大虾们对此问题都没有意见么,还是意见太多无从说起···

作者: dd890523   发布时间: 2010-09-10

先换风扇,然后再看看吧

作者: Tdog   发布时间: 2010-09-10

回复 Tdog


    系统风扇换过了···

作者: dd890523   发布时间: 2010-09-10

大虾们,该出手是就出手叻···

作者: dd890523   发布时间: 2010-09-10