今天早上看到两台750系统疯狂报错,两台机器做得是HA,报错信息还都一样,
8FBD189   0929072111 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929072011 T H fcs0           ADAPTER ERROR
B8FBD189   0929072011 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929072011 T H fcs0           ADAPTER ERROR
DE3B8540   0929071911 P H hdisk28        PATH HAS FAILED
B8FBD189   0929071911 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929071911 T H fcs0           ADAPTER ERROR
B8FBD189   0929071911 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929071911 T H fcs0           ADAPTER ERROR
DE3B8540   0929071911 P H hdisk7         PATH HAS FAILED
DE3B8540   0929071911 P H hdisk8         PATH HAS FAILED
DE3B8540   0929071911 P H hdisk9         PATH HAS FAILED
DE3B8540   0929071911 P H hdisk15        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk17        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk18        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk19        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk20        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk21        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk22        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk23        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk24        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk25        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk26        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk30        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk31        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk32        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk33        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk34        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk35        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk36        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk37        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk38        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk39        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk40        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk41        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk42        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk43        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk44        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk45        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk46        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk47        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk48        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk49        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk50        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk51        PATH HAS FAILED
DE3B8540   0929071911 P H hdisk52        PATH HAS FAILED
B8FBD189   0929071911 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929071811 T H fcs0           ADAPTER ERROR
DE3B8540   0929071811 P H hdisk2         PATH HAS FAILED
DE3B8540   0929071811 P H hdisk3         PATH HAS FAILED
DCB47997   0929071811 T H hdisk13        DISK OPERATION ERROR
DE3B8540   0929071811 P H hdisk4         PATH HAS FAILED
DCB47997   0929071811 T H hdisk12        DISK OPERATION ERROR
DCB47997   0929071811 T H hdisk14        DISK OPERATION ERROR
DCB47997   0929071811 T H hdisk13        DISK OPERATION ERROR
DE3B8540   0929071811 P H hdisk5         PATH HAS FAILED
DCB47997   0929071811 T H hdisk14        DISK OPERATION ERROR
DCB47997   0929071811 T H hdisk12        DISK OPERATION ERROR
DE3B8540   0929071811 P H hdisk6         PATH HAS FAILED
DE3B8540   0929071811 P H hdisk16        PATH HAS FAILED
DE3B8540   0929071811 P H hdisk27        PATH HAS FAILED
B8FBD189   0929071811 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929071811 T H fcs0           ADAPTER ERROR
DE3B8540   0929071811 P H hdisk10        PATH HAS FAILED
DE3B8540   0929071811 P H hdisk11        PATH HAS FAILED
DE3B8540   0929071811 P H hdisk29        PATH HAS FAILED
B8FBD189   0929071811 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929071811 T H fcs0           ADAPTER ERROR
DE3B8540   0929071811 P H hdisk12        PATH HAS FAILED
DE3B8540   0929071811 P H hdisk13        PATH HAS FAILED
DE3B8540   0929071811 P H hdisk14        PATH HAS FAILED
B8FBD189   0929071811 T S fscsi0         SOFTWARE PROGRAM ERROR
825849BF   0929071811 T H fcs0           ADAPTER ERROR
825849BF   0929071711 T H fcs0           ADAPTER ERROR

# errpt -aj 825849BF |more
LABEL:          FCS_ERR2
IDENTIFIER:     825849BF

Date/Time:       Thu Sep 29 09:58:59 BEIST 2011
Sequence Number: 439
Machine Id:      00F67A474C00
Node Id:         abv6db1
Class:           H
Type:            TEMP
Resource Name:   fcs0            
Resource Class:  adapter
Resource Type:   df1000fe
Location:        U5877.001.0084285-P1-C7-T1
VPD:            
        Part Number.................10N7255
        Serial Number...............1C045081AF
        Manufacturer................001C
        EC Level....................D77040
        Customer Card ID Number.....5774
        FRU Number..................10N7255
        Device Specific.(ZM)........3
        Network Address.............10000000C9A99D3A
        ROS Level and ID............02E8277F
        Device Specific.(Z0)........2057706D
        Device Specific.(Z1)........00000000
        Device Specific.(Z2)........00000000
        Device Specific.(Z3)........03000909
        Device Specific.(Z4)........FFE01212
        Device Specific.(Z5)........02E8277F
        Device Specific.(Z6)........06E12715
        Device Specific.(Z7)........07E1277F
        Device Specific.(Z8)........20000000C9A99D3A
        Device Specific.(Z9)........ZS2.71X15
        Device Specific.(ZA)........Z1F2.70A5
        Device Specific.(ZB)........Z2F2.71X15
        Device Specific.(ZC)........00000000

Description
ADAPTER ERROR

Probable Causes
ADAPTER HARDWARE
SYSTEM I/O BUS

Failure Causes
ADAPTER


# errpt -aj B8FBD189 |more
---------------------------------------------------------------------------
LABEL:          FSCSI_ERR6
IDENTIFIER:     B8FBD189

Date/Time:       Thu Sep 29 10:01:03 BEIST 2011
Sequence Number: 444
Machine Id:      00F67A474C00
Node Id:         abv6db1
Class:           S
Type:            TEMP
Resource Name:   fscsi0         

Description
SOFTWARE PROGRAM ERROR

Probable Causes
ADAPTER MICROCODE
SOFTWARE PROGRAM
SOFTWARE DEVICE DRIVER

Failure Causes
ADAPTER MICROCODE
SOFTWARE PROGRAM
SOFTWARE DEVICE DRIVER

        Recommended Actions
        IF PROBLEM PERSISTS THEN DO THE FOLLOWING
        CONTACT APPROPRIATE SERVICE REPRESENTATIVE

Detail Data
SENSE DATA
0000 0000 0000 00A1 0000 0006 0200 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0001 0800 0000 0000
0001 0D00 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 C02F 0000 A812 0002 0000 0000 0000 0000 0001 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0033 5005 0763
0A13 07BE 5005 0763 0AFF C7BE 0200 0000 0000 0000 0000 0000 0000 0000 0000 0000
101D 3000

因为环境所限制暂时不能到现场,存储是台8700也连不了,交换机也不能远程,所以不知道是哪出了问题,小弟初步判定是存储控制器或者交换机有问题,因为不可能两台的HBA卡同时坏掉,不知道是不是可以这样理解,请大哥们赐教~!

作者: hegang198772   发布时间: 2011-09-29

以后做项目,通通把设备的管理端口连到管理网

作者: troyme   发布时间: 2011-09-29