P55A报错了,新手请大伙帮忙
时间:2011-03-16
来源:互联网
Show details
1. 50002920 2011-03-16 04:04:50 'Service Process' 'Predictive Erro' 'B181201B'
2. 5000291A 2011-03-16 04:04:35 'Power/Cooling S' 'Unrecoverable E' '11002630'
3. 50002917 2011-03-16 04:03:54 'Power Supply' 'Unrecoverable E' '11001510'
4. 50002893 2011-03-16 04:02:55 'Power Supply' 'Unrecoverable E' '11001510'
5. 50002794 2011-03-16 03:54:43 'Service Process' 'Predictive Erro' 'B181201B'
6. 5000278D 2011-03-16 03:54:27 'Power/Cooling S' 'Unrecoverable E' '110000AC'
7. 5000278A 2011-03-16 03:53:53 'Power Supply' 'Unrecoverable E' '11001513'
8. 50002789 2011-03-16 03:53:45 'Power Supply' 'Unrecoverable E' '11001520'
9. 50002704 2011-03-16 03:52:41 'Power Supply' 'Unrecoverable E' '11001520'
10. 5000260D 2011-03-16 03:48:51 'Service Process' 'Predictive Erro' 'B181201B'
11. 50002604 2011-03-16 03:48:35 'Power/Cooling S' 'Unrecoverable E' '110000AC'
12. 50002601 2011-03-16 03:48:00 'Power Supply' 'Unrecoverable E' '11001513'
13. 50002600 2011-03-16 03:47:53 'Power Supply' 'Unrecoverable E' '11001520'
14. 5000258D 2011-03-16 03:45:40 'Service Process' 'Predictive Erro' 'B181201B'
15. 50002587 2011-03-16 03:45:25 'Power/Cooling S' 'Unrecoverable E' '110000AC'
16. 50002584 2011-03-16 03:44:50 'Power Supply' 'Unrecoverable E' '11001513'
17. 50002583 2011-03-16 03:44:43 'Power Supply' 'Unrecoverable E' '11001520'
97. Next page
98. Return to previous menu
99. Log out
S1> 1
| Platform Event Log - 50002920 |
| Created at : 03/16/2011 04:04:49 |
| Driver Name : fips240/b1118a_0637.240 |
| Subsystem : Service Processor Firmware |
| Event Severity : Predictive Error |
| Action Flags : Report to Operating System |
| : Service Action Required |
| : HMC Call Home |
| : Service Processor Call Home Required |
| Action Status : Processed |
| |
| Primary System Reference Code |
| |
| Reference Code : B181201B |
| Hex Words 2 - 5 : 010000F0 28D97610 C1802000 000000FF |
| Hex Words 6 - 9 : 00000001 00000000 00000000 00000000 |
| |
| |
| Maintenance Procedure Required |
| Priority : Mandatory, replace all with this type as a unit |
| Procedure Number : FSPSP04 |
| |
| Maintenance Procedure Required |
PRESS ENTER TO CONTINUE:
| Priority : Medium Priority |
| Procedure Number : FSPSP06
| Platform Event Log - 5000291A |
| Created at : 03/16/2011 04:04:35 |
| Driver Name : fips240/b1118a_0637.240 |
| Subsystem : Power/Cooling Subsystem |
| Event Severity : Unrecoverable Error |
| Action Flags : Report to Operating System |
| : Service Action Required |
| : HMC Call Home |
| : Service Processor Call Home Required |
| Action Status : Processed |
| |
| Primary System Reference Code |
| |
| Reference Code : 11002630 |
| Hex Words 2 - 5 : 003C0001 00000000 00000000 00000000 |
| Hex Words 6 - 9 : 00000000 00000000 00000000 00000000 |
| |
| |
| Maintenance Procedure Required |
| Priority : Lowest priority replacement |
| Location Code : U787B.001.DNWGY5H |
| Procedure Number : PWR1918 |
| Machine Type Model : 9133-55A |
PRESS ENTER TO CONTINUE:
| Serial Number : 06CF31G |
| |
| Normal Hardware FRU |
| Priority : Lowest priority replacement |
| Location Code : U787B.001.DNWGY5H-P1 |
| Part Number : 10N6472 |
| CCIN : 28D9 |
| Serial Number : YL16HA89R05N |
| Machine Type Model : 9133-55A |
| Serial Number : 06CF31G
我查过之前的帖子,有的说是风扇,有的是电源,但是我从550的电源拆过来装上去后,还是不行,换了风扇也是不行!这台55A是单cpu加cpu堵头启动的,2路1.9的频率。各位帮我看一下是什么问题吗?
1. 50002920 2011-03-16 04:04:50 'Service Process' 'Predictive Erro' 'B181201B'
2. 5000291A 2011-03-16 04:04:35 'Power/Cooling S' 'Unrecoverable E' '11002630'
3. 50002917 2011-03-16 04:03:54 'Power Supply' 'Unrecoverable E' '11001510'
4. 50002893 2011-03-16 04:02:55 'Power Supply' 'Unrecoverable E' '11001510'
5. 50002794 2011-03-16 03:54:43 'Service Process' 'Predictive Erro' 'B181201B'
6. 5000278D 2011-03-16 03:54:27 'Power/Cooling S' 'Unrecoverable E' '110000AC'
7. 5000278A 2011-03-16 03:53:53 'Power Supply' 'Unrecoverable E' '11001513'
8. 50002789 2011-03-16 03:53:45 'Power Supply' 'Unrecoverable E' '11001520'
9. 50002704 2011-03-16 03:52:41 'Power Supply' 'Unrecoverable E' '11001520'
10. 5000260D 2011-03-16 03:48:51 'Service Process' 'Predictive Erro' 'B181201B'
11. 50002604 2011-03-16 03:48:35 'Power/Cooling S' 'Unrecoverable E' '110000AC'
12. 50002601 2011-03-16 03:48:00 'Power Supply' 'Unrecoverable E' '11001513'
13. 50002600 2011-03-16 03:47:53 'Power Supply' 'Unrecoverable E' '11001520'
14. 5000258D 2011-03-16 03:45:40 'Service Process' 'Predictive Erro' 'B181201B'
15. 50002587 2011-03-16 03:45:25 'Power/Cooling S' 'Unrecoverable E' '110000AC'
16. 50002584 2011-03-16 03:44:50 'Power Supply' 'Unrecoverable E' '11001513'
17. 50002583 2011-03-16 03:44:43 'Power Supply' 'Unrecoverable E' '11001520'
97. Next page
98. Return to previous menu
99. Log out
S1> 1
| Platform Event Log - 50002920 |
| Created at : 03/16/2011 04:04:49 |
| Driver Name : fips240/b1118a_0637.240 |
| Subsystem : Service Processor Firmware |
| Event Severity : Predictive Error |
| Action Flags : Report to Operating System |
| : Service Action Required |
| : HMC Call Home |
| : Service Processor Call Home Required |
| Action Status : Processed |
| |
| Primary System Reference Code |
| |
| Reference Code : B181201B |
| Hex Words 2 - 5 : 010000F0 28D97610 C1802000 000000FF |
| Hex Words 6 - 9 : 00000001 00000000 00000000 00000000 |
| |
| |
| Maintenance Procedure Required |
| Priority : Mandatory, replace all with this type as a unit |
| Procedure Number : FSPSP04 |
| |
| Maintenance Procedure Required |
PRESS ENTER TO CONTINUE:
| Priority : Medium Priority |
| Procedure Number : FSPSP06
| Platform Event Log - 5000291A |
| Created at : 03/16/2011 04:04:35 |
| Driver Name : fips240/b1118a_0637.240 |
| Subsystem : Power/Cooling Subsystem |
| Event Severity : Unrecoverable Error |
| Action Flags : Report to Operating System |
| : Service Action Required |
| : HMC Call Home |
| : Service Processor Call Home Required |
| Action Status : Processed |
| |
| Primary System Reference Code |
| |
| Reference Code : 11002630 |
| Hex Words 2 - 5 : 003C0001 00000000 00000000 00000000 |
| Hex Words 6 - 9 : 00000000 00000000 00000000 00000000 |
| |
| |
| Maintenance Procedure Required |
| Priority : Lowest priority replacement |
| Location Code : U787B.001.DNWGY5H |
| Procedure Number : PWR1918 |
| Machine Type Model : 9133-55A |
PRESS ENTER TO CONTINUE:
| Serial Number : 06CF31G |
| |
| Normal Hardware FRU |
| Priority : Lowest priority replacement |
| Location Code : U787B.001.DNWGY5H-P1 |
| Part Number : 10N6472 |
| CCIN : 28D9 |
| Serial Number : YL16HA89R05N |
| Machine Type Model : 9133-55A |
| Serial Number : 06CF31G
我查过之前的帖子,有的说是风扇,有的是电源,但是我从550的电源拆过来装上去后,还是不行,换了风扇也是不行!这台55A是单cpu加cpu堵头启动的,2路1.9的频率。各位帮我看一下是什么问题吗?
作者: Iason 发布时间: 2011-03-16
110000AC这个说明出现过非正常断电,可以忽略
作者: mi_zy 发布时间: 2011-03-16
非正常断电?因为这台机一直很久没用过了
作者: Iason 发布时间: 2011-03-16
相关阅读 更多
热门阅读
-
office 2019专业增强版最新2021版激活秘钥/序列号/激活码推荐 附激活工具
阅读:74
-
如何安装mysql8.0
阅读:31
-
Word快速设置标题样式步骤详解
阅读:28
-
20+道必知必会的Vue面试题(附答案解析)
阅读:37
-
HTML如何制作表单
阅读:22
-
百词斩可以改天数吗?当然可以,4个步骤轻松修改天数!
阅读:31
-
ET文件格式和XLS格式文件之间如何转化?
阅读:24
-
react和vue的区别及优缺点是什么
阅读:121
-
支付宝人脸识别如何关闭?
阅读:21
-
腾讯微云怎么修改照片或视频备份路径?
阅读:28